edwina@edwin-pump.com

Water pressure systems are expected to deliver consistent flow, protect pumps from unnecessary cycling, and operate reliably under changing demand. In residential water supply, irrigation, agricultural installations, commercial buildings, and general fluid-handling applications, the pressure tank is one of the most important supporting components in the system. Although it does not usually attract as much attention as the pump itself, the tank has a direct influence on system stability, energy consumption, service life, and user comfort.
The WCF Series horizontal water pressure tank is designed for applications requiring replaceable membrane technology, carbon steel construction, flexible pressure selection, and practical connection options. The series covers tank capacities from 60 liters to 300 liters, with maximum pressure ratings of 6, 8, 10, or 16 bar depending on the selected model. Most of the smaller models use a 1-inch connector, while the larger 200-liter and 300-liter models use a 1.5-inch connector to support greater water flow.
These tanks are suitable for use with domestic booster pumps, deep well pumps, submersible pumps, surface pumps, intelligent booster systems, irrigation equipment, and other pressurized water installations. Their replaceable membrane design provides a maintainable alternative to permanently sealed pressure vessels, while the carbon steel flange and carefully selected membrane materials support long-term use across a wide range of operating conditions.
The product is manufactured and supplied by Taizhou Edwin Electric Co., Ltd., an integrated pump and water-system equipment enterprise with experience in research and development, mass production, export, and one-stop procurement support. The company’s broader product portfolio includes deep well pumps, submersible pumps, domestic booster pumps, circulation pumps, solar water pumps, intelligent booster pumps, commercial multistage pumps, pump accessories, pipes, and valves.

WCF Series 6 Bar to 16 Bar 1 Inch Connector Horizontal Water Pressure Tank
A pressure tank is used to store pressurized water and reduce the frequency with which a pump must start and stop. Without a pressure tank, a pump may need to run every time a tap is opened, a toilet is flushed, a sprinkler zone is activated, or a small water demand occurs. Frequent cycling can create mechanical and electrical stress, increase energy consumption, and shorten the service life of the pump and control equipment.
When a pressure tank is installed correctly, the pump fills the tank until the system reaches its cut-out pressure. The stored water can then supply short-term demand without immediately starting the pump. As water leaves the tank, the internal pressure decreases. When the system reaches the cut-in pressure, the pump starts again and restores the stored pressure.
This operating principle provides several important benefits. It reduces pump cycling, smooths pressure fluctuations, provides a reserve of pressurized water, and helps the pump operate for longer periods instead of repeatedly starting for very short intervals. In a properly designed system, the pressure tank also works together with pressure switches, electronic controllers, check valves, pressure gauges, and safety devices to create a stable and efficient water supply installation.
The tank does not replace a pump. Instead, it supports the pump by acting as a hydraulic buffer. Selecting the correct tank capacity, pressure rating, membrane material, precharge pressure, connection size, and installation position is therefore essential for achieving good system performance.
The WCF Series consists of horizontal water pressure tanks with replaceable membranes and carbon steel flanges. The available models are WCF60L, WCF80L, WCF100L, WCF150L, WCF200L, and WCF300L. The model number generally indicates the nominal tank capacity in liters.
The smaller WCF60L, WCF80L, and WCF100L models are available with maximum pressure options of 6, 8, 10, and 16 bar. The WCF150L, WCF200L, and WCF300L models are listed with maximum pressure options of 10 and 16 bar. This range allows system designers, installers, and distributors to select a tank according to the working pressure and water-demand requirements of the project.
The WCF60L, WCF80L, and WCF100L models use a 1-inch connector. The WCF200L and WCF300L models use a 1.5-inch connector, while the WCF150L model is listed with a 1-inch connector. The larger connector on the high-capacity models helps reduce flow restriction and makes the tank more suitable for larger pump systems.
The replaceable membrane is a central feature of this product family. Instead of relying on a permanently sealed internal bladder that cannot be changed, the replaceable membrane structure allows maintenance personnel to replace the membrane when required. This can extend the usable service life of the tank and may reduce the need to replace the complete vessel after membrane wear.
| Model | Maximum Pressure Options | Length | Height | Precharge Pressure | Connector | Packing Volume |
| WCF60L | 6, 8, 10, or 16 bar | 680 mm | 408 mm | 1.8–2.0 bar | 1 inch | 0.1054 CBM |
| WCF80L | 6, 8, 10, or 16 bar | 640 mm | 470 mm | 1.8–2.0 bar | 1 inch | 0.1398 CBM |
| WCF100L | 6, 8, 10, or 16 bar | 725 mm | 470 mm | 1.8–2.0 bar | 1 inch | 0.1616 CBM |
| WCF150L | 10 or 16 bar | 980 mm | 532 mm | 2.5 or 4.0 bar | 1 inch | 0.2803 CBM |
| WCF200L | 10 or 16 bar | 912 mm | 660 mm | 2.5 or 4.0 bar | 1.5 inches | 0.4134 CBM |
| WCF300L | 10 or 16 bar | 1192 mm | 660 mm | 2.5 or 4.0 bar | 1.5 inches | 0.5353 CBM |
The listed dimensions are useful for preliminary planning, but installers should confirm the final product drawing, port position, support requirements, and service clearance before installation. The tank must be positioned on a stable surface or suitable support structure capable of carrying the filled weight and resisting vibration from connected equipment.
The membrane separates the water from the air or gas chamber inside the pressure tank. This separation is important because it prevents direct contact between stored water and the internal air charge. As water enters the tank, the membrane moves and compresses the air cushion. As water leaves the tank, the compressed air pushes the membrane back and forces water into the system.
A replaceable membrane provides a practical maintenance advantage. Internal membranes can eventually experience fatigue, stretching, abrasion, chemical exposure, or deterioration caused by unsuitable water conditions. In a replaceable design, the service technician may be able to remove the flange, inspect the vessel, install a compatible new membrane, and return the tank to service without discarding the complete pressure vessel.
This feature may be particularly valuable in commercial installations, agricultural systems, building water supply projects, and remote locations where equipment replacement creates significant labor or transportation costs. It also supports a more sustainable maintenance approach because the metal pressure vessel can remain in service when its structural condition is still acceptable.
Membrane selection must match the application. The product information identifies Butyl and EPDM membrane options. Butyl is commonly selected for its good flexibility, low gas permeability, and suitability for many pressurized water applications. EPDM is known for broad water-service use and resistance to many environmental conditions. The correct material should be selected according to water chemistry, temperature, pressure, local regulations, and the intended use of the water.
The membrane should not be exposed to conditions outside the approved operating range. Abrasive particles, aggressive chemicals, oils, excessive temperature, and improper pressure adjustment can reduce membrane life. For potable-water systems, buyers should also confirm that the selected membrane and complete tank configuration comply with the applicable local drinking-water requirements.
The WCF Series uses a carbon steel flange. The flange is an important mechanical interface between the tank body and the replaceable membrane assembly. It must provide reliable compression, maintain a secure seal, and withstand the pressure generated during operation.
Carbon steel remains widely used in pressure-vessel applications because it offers a strong balance between mechanical strength, manufacturing practicality, availability, and cost. Compared with some alternative materials, carbon steel can provide a robust structure at a commercially competitive price. This helps make the WCF Series suitable for projects where buyers require dependable pressure storage without unnecessary material costs.
The flange and vessel must be treated as a complete pressure-containing assembly. The pressure rating selected by the buyer must not exceed the pressure rating of the entire system. A tank rated for 16 bar, for example, should not be connected to a pump system or control arrangement that can generate pressure above the tank’s approved maximum. Pressure relief devices, properly adjusted controls, and suitable pipework remain necessary.
External protection is also important. Carbon steel equipment should be protected from prolonged exposure to corrosive environments, standing water, salt spray, aggressive chemicals, and mechanical damage. Correct installation, appropriate surface protection, drainage, and periodic inspection can help preserve the tank body and flange.
The supplied product information contains two temperature references. The general product content lists a working temperature of -10°C to 99°C for both Butyl and EPDM membranes, while the technical specification lists -20°C to 99°C for both materials. Because these values are not identical, the buyer should confirm the final approved temperature range with the supplier before placing an order or designing an installation.
This confirmation is especially important for outdoor systems, cold-climate installations, solar pumping projects, agricultural applications, and equipment exposed to freezing conditions. Water expands when it freezes, and freezing can damage the membrane, tank, connectors, valves, or connected piping. A pressure tank should never be allowed to freeze unless the complete installation has been specifically designed and protected for that condition.
The upper temperature limit is equally important. Operating continuously near the maximum temperature can accelerate membrane aging and may influence the pressure behavior of the air chamber. If the tank is used with hot water, heated circulation systems, or process water, the temperature, water chemistry, and pressure conditions should be reviewed together rather than considered separately.
Buyers should request confirmation of the following points before final selection: the approved temperature range for the chosen membrane, whether the tank is suitable for potable water, the maximum continuous operating pressure, the test pressure, the membrane material actually supplied, and any restrictions relating to water chemistry.
The WCF Series offers several pressure ratings. The 6-bar, 8-bar, 10-bar, and 16-bar options allow the product to serve different system designs. Low-pressure domestic systems may require a 6-bar or 8-bar configuration, while larger booster systems and commercial installations may require a 10-bar or 16-bar configuration.
The maximum pressure rating is not the same as the normal operating pressure. A system should be designed so that the usual pressure remains within a suitable margin below the maximum permitted pressure. The pump shut-off head, static pressure, thermal expansion, pressure-switch setting, elevation changes, and possible transient pressure must all be considered.
Precharge pressure is the air pressure inside the tank before water enters the water chamber. The listed precharge values are 1.8–2.0 bar for the WCF60L, WCF80L, and WCF100L models, and 2.5 or 4.0 bar for the WCF150L, WCF200L, and WCF300L models. The correct precharge depends on the pressure-switch settings and application design.
In many conventional systems, the precharge is set below the pump cut-in pressure. A common design practice is to set the precharge approximately 0.1 to 0.2 bar below the cut-in pressure, although the exact value should follow the manufacturer’s installation instructions and the requirements of the specific control system. The measurement should normally be taken with the tank isolated from the water system and fully depressurized on the water side.
Incorrect precharge can cause poor performance. If the precharge is too high, the tank may accept too little water and the pump may cycle frequently. If it is too low, the membrane may move excessively, the useful drawdown may be reduced, and the membrane may experience unnecessary stress. Pressure should be checked periodically because air can gradually diffuse or escape through the valve over time.
One of the main advantages of the WCF Series over basic non-serviceable pressure tanks is the replaceable membrane. In a fixed-bladder design, membrane failure may require complete tank replacement even when the metal shell remains structurally sound. The WCF design offers the possibility of replacing the membrane independently, subject to inspection and manufacturer approval.
This can improve lifecycle value. The initial purchase price is only one part of total cost. Labor, downtime, transport, disposal, spare-parts availability, and system interruption can be more expensive than the original component. A serviceable membrane may help reduce these costs, particularly for large tanks and commercial installations.
Another advantage is the broad pressure selection. Some competing products are available only in a single pressure rating or a narrow range of sizes. The WCF Series provides multiple pressure options across its smaller models and larger high-capacity configurations. This allows distributors and system integrators to use one product family across different projects.
The series also combines practical connection sizes with a capacity range suitable for both compact and larger systems. The 1-inch connector on the smaller models supports common domestic and light-commercial installations. The 1.5-inch connector on the 200-liter and 300-liter models is better suited to higher-flow systems where a small connection could create excessive velocity or pressure loss.
The horizontal format can provide installation flexibility. Depending on the layout, a horizontal vessel may fit beneath a pump, beside a booster assembly, inside a plant room, or in an equipment area where vertical clearance is limited. It may also be easier to integrate into packaged pump skids and compact pressure-boosting systems.
Cost competitiveness is another potential advantage. Carbon steel construction, standardized capacities, replaceable internal components, and coordinated manufacturing can help provide a practical balance between durability and purchase cost. The final economic result depends on the selected pressure rating, membrane material, order quantity, shipping terms, and installation requirements.
In houses, apartments, villas, and small residential buildings, the pressure tank can reduce pump starts caused by small water demands. It may be connected to a surface booster pump, a domestic pressure pump, or an intelligent booster pump. The tank helps supply short water draws and can make pressure changes less noticeable to users.
In a domestic application, the installer should consider the number of occupants, fixture flow rates, pump capacity, cut-in and cut-out pressures, available space, and required water reserve. The tank should be installed with a pressure gauge, isolation valve, drain arrangement, and suitable non-return protection where required.
Deep well pumps and submersible pumps often supply water from wells, boreholes, underground reservoirs, or storage tanks. A pressure tank installed at the discharge side can help control pump cycling and support stable pressure in the distribution network.
The tank does not normally sit inside the well. It is generally installed in the building, pump room, or surface control area, where technicians can inspect the pressure, service the membrane, and access the connection. The system must include suitable protection against dry running, excessive pump head, water hammer, and contamination.
Irrigation systems may experience changing demand when valves open and close or when different zones are activated. A pressure tank can buffer these variations and reduce rapid cycling of a surface pump or booster pump. It can be used in small farm systems, greenhouse irrigation, garden irrigation, and selected agricultural water-supply installations.
For larger irrigation networks, the tank should be selected together with the pump, pipe diameter, irrigation valves, filtration equipment, and control strategy. Sand, silt, fertilizers, and chemicals can affect membrane life, so water quality and upstream filtration should be evaluated.
Commercial buildings often require stable water pressure at different times of day. Offices, hotels, restaurants, workshops, schools, and small industrial facilities may benefit from pressure storage combined with a booster pump set.
The WCF150L, WCF200L, and WCF300L models may be considered for applications requiring greater storage capacity. However, a tank should not be selected solely by volume. The designer must calculate drawdown, peak flow, pump starts per hour, pressure range, and the effect of multiple simultaneous users.
Solar pumping systems can experience variable power input because of changing sunlight. A pressure tank can provide hydraulic storage and reduce the immediate impact of short-term changes in pump output. It can be used as part of a solar water-supply solution, although it does not replace a water storage reservoir when large quantities of water must be stored for periods without sunlight.
In solar applications, the tank pressure rating, controller behavior, pump curve, and available solar power must be reviewed together. An intelligent controller may change pump speed or operating pressure, and the tank precharge must be compatible with that control strategy.
Circulation pumps and closed-loop systems may use pressure vessels to accommodate fluid expansion and maintain stable system pressure. The suitability of the WCF Series for a particular heating, cooling, or circulation application depends on the fluid type, temperature, chemical additives, pressure, and membrane compatibility.
Because the available product information identifies Butyl and EPDM membranes and a maximum temperature near 99°C, engineers should confirm whether the specific tank configuration is approved for the selected HVAC fluid. A tank intended for clean water should not automatically be assumed suitable for glycol mixtures, oils, aggressive process fluids, or other specialized liquids.
Taizhou Edwin Electric Co., Ltd. was founded in 2008 and operates as an integrated manufacturing enterprise focused on independent research and development, mass production, and global export. Although the company is widely associated with pumps, its product range also includes water-treatment peripheral products and pressure-system accessories such as tanks.
An integrated manufacturing structure can create advantages in product coordination. Pressure tanks are often used together with pumps, controllers, valves, pipes, pressure switches, gauges, and electrical protection devices. A manufacturer with experience across these categories can better understand how the components interact in a complete water system.
The company’s pump portfolio includes deep well pumps, submersible pumps, domestic booster pumps, circulation pumps, solar water pumps, intelligent booster pumps, commercial multistage pumps, surface pumps, garden pumps, pool and spa pumps, end-suction pumps, and pump accessories. This breadth supports one-stop procurement for distributors, contractors, engineering companies, and industrial buyers.
Manufacturing quality begins with design control. Pressure tanks must be developed around the required vessel dimensions, pressure class, flange structure, membrane geometry, connector size, and installation orientation. Consistent design documentation helps reduce variation between production batches and supports more reliable product selection by distributors.
Material control is also important. The carbon steel vessel, flange, membrane, air valve, connector, sealing elements, and protective coatings all influence service performance. A professional manufacturing process should verify incoming materials, maintain traceability where required, and ensure that component specifications match the approved product configuration.
Forming and welding processes must be controlled carefully because the tank body is a pressure-containing component. Dimensional accuracy, weld consistency, surface condition, flange alignment, and connection quality all influence the finished product. After manufacturing, pressure-related inspection and leak testing are essential parts of quality assurance.
Membrane installation requires equal attention. The membrane must be correctly positioned, secured, and sealed without twisting, pinching, or excessive mechanical stress. Incorrect assembly can reduce usable volume, cause leakage, or lead to premature fatigue. A repeatable assembly process and final inspection help ensure that the tank performs as intended.
Pressure and precharge verification are also important. A tank may be mechanically sound but still perform poorly if its precharge is outside the specified range. Factory inspection should therefore include checks of the air valve, pressure condition, connection area, external appearance, and packaging protection.
Mass-production capability can provide stable supply and support consistent delivery for international buyers. It may also allow the manufacturer to optimize production fixtures, inspection procedures, packaging methods, and spare-parts planning. For wholesalers and project buyers, dependable supply can be as important as the technical specification itself.
When selecting a pressure tank, buyers should evaluate more than the appearance of the finished product. Quality control should cover raw materials, welding, pressure testing, membrane assembly, dimensional inspection, surface protection, labeling, packaging, and documentation.
The tank body should be checked for visible deformation, unacceptable corrosion, dents, cracks, and coating defects. The flange should be flat and correctly aligned. The connector should be free from damage and compatible with the intended pipe standard. Threads or connection surfaces should be protected during transport and storage.
Pressure testing helps identify leaks or structural problems before shipment. The exact test method and test pressure should be defined by the manufacturer’s quality system and applicable standards. Buyers serving regulated markets should request relevant test records or compliance documents when required.
Packaging is particularly important for large horizontal tanks. The product information includes packing volumes ranging from 0.1054 CBM for the WCF60L to 0.5353 CBM for the WCF300L. These values are useful for export planning, container loading, warehouse layout, and freight-cost estimation. Packaging should protect the flange, connector, membrane-related parts, and painted surfaces from impact and moisture.
International customers may also require product labels, manuals, spare membrane information, certificates, inspection reports, country-of-origin documentation, and customized packaging. A manufacturer experienced in global export can help buyers prepare the documentation required for distribution and project delivery.
The tank should be installed by qualified personnel who understand pressure systems and local regulations. Before installation, verify the model, capacity, maximum pressure, membrane material, connector size, precharge pressure, and dimensions.
Install the tank on a stable, level, and sufficiently strong support. A filled tank is significantly heavier than an empty tank, and the support must accommodate the combined weight of the vessel and water. Avoid placing the tank where it may be struck by vehicles, tools, moving machinery, or unprotected pipework.
Provide enough clearance for inspection and membrane replacement. Because the WCF Series uses a replaceable membrane, the installation should not block access to the flange or prevent removal of the relevant components. Service space is part of the installation design, not an optional convenience.
Use suitable isolation valves so the tank can be removed or serviced without draining the entire system. A pressure gauge should be installed where system pressure can be read easily. Depending on the application, the system may also require a pressure relief valve, drain valve, non-return valve, pressure switch, electronic controller, and filtration equipment.
Before commissioning, inspect all connections and confirm that the tank is correctly supported. Check the precharge with the water side isolated and depressurized. Adjust the precharge only within the approved range and according to the pressure settings of the complete system.
After filling the system, open valves gradually to reduce the risk of water hammer. Check for leaks around the connector, flange, drain points, and associated pipework. Observe the pump’s start and stop behavior and confirm that the pressure remains within the planned operating range.
Regular inspection can help identify problems before they cause system downtime. The inspection interval depends on the application, water quality, pressure, temperature, operating hours, and local regulations. Commercial and industrial systems may require a documented maintenance schedule.
Check the tank for external corrosion, coating damage, unusual noise, deformation, leakage, and unstable pressure. Inspect the connector and surrounding pipework for vibration or stress. Confirm that the pressure gauge gives a reliable reading and that safety devices remain functional.
Precharge should be checked periodically, especially if the pump begins cycling more frequently or the available drawdown appears to decrease. The tank must be isolated from the water supply and depressurized on the water side before measuring or adjusting the air pressure.
If the membrane is suspected to be damaged, isolate the tank and release pressure safely. Do not disassemble a pressurized vessel. Replacement should be carried out using a compatible membrane and correct sealing components. The flange bolts or fasteners should be tightened evenly according to the manufacturer’s instructions.
After membrane replacement, the tank should be inspected, correctly precharged, and tested before being returned to service. If the carbon steel shell, flange, welds, or connection area show serious corrosion or structural damage, replacing only the membrane may not be sufficient. The complete tank should be assessed by a qualified technician.
Model selection begins with the required water demand. A small domestic system may use the WCF60L, WCF80L, or WCF100L, while a larger commercial or agricultural system may require the WCF150L, WCF200L, or WCF300L. The objective is to provide sufficient usable drawdown and reduce pump cycling without creating unnecessary cost, weight, or space requirements.
The desired pressure range must then be considered. Select a maximum pressure rating that exceeds the normal system operating pressure by a suitable safety margin and remains compatible with the pump shut-off head and control settings. Never select a tank based only on the pump’s normal running pressure.
Connection size is another important factor. A 1-inch connector may be appropriate for compact systems, but a higher-flow installation may benefit from the 1.5-inch connector available on the WCF200L and WCF300L models. Pipe diameter, flow rate, velocity, fittings, and pressure loss should be evaluated together.
Installation space must also be confirmed. Review the model length, height, support arrangement, access for service, and transport route. The WCF60L has a listed length of 680 mm and height of 408 mm, while the WCF300L has a listed length of 1192 mm and height of 660 mm. These differences can significantly affect equipment-room planning.
Finally, confirm the membrane material, temperature range, water compatibility, precharge pressure, certification requirements, packaging, and spare-parts availability. A technically suitable tank can still be unsuitable if it cannot meet the documentation or regulatory requirements of the destination market.
For international distributors, the WCF Series offers a practical product family that can be combined with multiple pump categories. A buyer may source a pressure tank together with a deep well pump, submersible pump, surface pump, booster pump, circulation pump, intelligent controller, pipes, valves, and other accessories.
This one-stop approach can simplify procurement, reduce the number of separate suppliers, and improve compatibility between components. It may also allow distributors to create complete water-pressure packages for residential, agricultural, commercial, or industrial customers.
Taizhou Edwin Electric Co., Ltd. established related import and export organizations to support procurement planning, order tracking, cross-border delivery, and foreign-trade services. This structure is relevant to overseas customers who require assistance with production coordination, packaging, shipment scheduling, and export documentation.
The company has served the global market since its early development and focuses on medium-to-high-end pump and water-system products. Its experience in new-energy and intelligent technologies, including solar water pumps and intelligent booster pumps, also supports applications where pressure tanks are integrated into modern automated systems.
For project orders, buyers should provide complete technical information at the quotation stage. Useful information includes required capacity, pressure rating, connector standard, membrane material, operating temperature, water type, target market, certification requirements, packaging expectations, and estimated order quantity.
Product sustainability should be evaluated over the entire service life rather than by purchase price alone. A pressure tank that reduces pump cycling may help reduce wear and unnecessary energy use. A replaceable membrane may allow the vessel to remain in service longer when the shell is still structurally sound.
Longer service life can reduce the frequency of transportation, disposal, and replacement manufacturing. Carbon steel is also widely recyclable at the end of its service life, although recycling and disposal must follow local requirements and the tank must be made safe before handling.
Correct sizing is essential to achieving these benefits. An undersized tank may cycle too frequently, while an oversized tank may increase material use and installation cost without providing a proportional benefit. Efficient operation depends on a balanced design involving the pump, tank, controls, pipework, and actual water demand.
Maintenance also contributes to lifecycle performance. A properly precharged tank with a healthy membrane can operate more efficiently than a neglected tank. Regular inspection, timely membrane replacement, corrosion control, and correct pressure settings all help protect the initial investment.
A pressure tank is a pressure-containing product and must be treated accordingly. Do not drill, weld, cut, modify, or otherwise alter the vessel without written approval from the manufacturer and an appropriately qualified pressure-equipment professional.
Do not exceed the marked or specified maximum pressure. The complete system must include suitable control and protection devices. Pump shut-off pressure, pressure-switch failure, thermal expansion, blocked outlets, and water hammer can all create hazardous conditions if they are not considered during design.
Never open the flange or remove the membrane while the tank is pressurized. Isolate the tank, close the relevant valves, release pressure safely, and verify zero pressure before beginning service work. If the tank shows severe corrosion, bulging, cracking, leakage from a structural area, or unexplained pressure loss, remove it from service until it has been assessed.
Installation and maintenance should comply with local plumbing, pressure-equipment, electrical, building, and occupational-safety requirements. The product information supplied for a general application should not be treated as a substitute for project-specific engineering review.
The tank stores pressurized water and helps reduce pump starting and stopping. It acts as a hydraulic buffer, supports more stable pressure, and can reduce wear caused by frequent pump cycling.
It means the internal water-separation membrane can be removed and replaced when necessary, subject to inspection and the manufacturer’s service instructions. This may allow the pressure vessel to remain in use instead of being replaced as a complete unit.
The listed capacities are 60 liters, 80 liters, 100 liters, 150 liters, 200 liters, and 300 liters, represented by the models WCF60L, WCF80L, WCF100L, WCF150L, WCF200L, and WCF300L.
The WCF60L, WCF80L, WCF100L, and WCF150L models are listed with a 1-inch connector. The WCF200L and WCF300L models are listed with a 1.5-inch connector.
The WCF60L, WCF80L, and WCF100L are listed with 6, 8, 10, and 16 bar options. The WCF150L, WCF200L, and WCF300L are listed with 10 and 16 bar options.
The smaller models are listed with a precharge pressure of 1.8–2.0 bar. The WCF150L, WCF200L, and WCF300L are listed with precharge options of 2.5 or 4.0 bar. The final setting should be matched to the system’s cut-in pressure and confirmed against the installation instructions.
The product information identifies Butyl and EPDM membrane options. The correct choice depends on water chemistry, temperature, pressure, and the intended application.
The supplied information contains two ranges: -10°C to 99°C and -20°C to 99°C. Because of this discrepancy, the buyer should confirm the approved temperature range for the exact model and membrane configuration before use.
It may be suitable for certain water-supply applications, but potable-water approval must be confirmed for the specific configuration and destination market. Buyers should request the relevant compliance documentation before using the tank in a drinking-water system.
It can be considered as part of a solar pumping system where hydraulic pressure storage is required. The tank must be coordinated with the solar pump, controller, pressure settings, available sunlight, and water-demand profile.
Suitability depends on the temperature, fluid composition, membrane material, pressure, and applicable approvals. The buyer should obtain confirmation before using the tank with glycol mixtures, heating fluid, chemicals, or other liquids besides the intended water service.
Isolate the tank from the water system, release the water-side pressure safely, and then measure the air pressure using a suitable gauge. Never measure or adjust the precharge while the tank remains connected to pressurized water unless the manufacturer specifically instructs otherwise.
Key differentiating features include the replaceable membrane, carbon steel flange, multiple pressure options, several capacity choices, horizontal installation format, and larger 1.5-inch connections on the highest-capacity models.
Residential installers, pump distributors, agricultural contractors, commercial building contractors, water-treatment companies, equipment integrators, and industrial procurement teams can use the series where a reliable pressure-storage component is required.
The WCF Series horizontal water pressure tank is designed to provide stable pressure storage for a wide range of pump and water-supply systems. Its replaceable membrane, carbon steel flange, multiple capacities, flexible pressure ratings, and practical connector options make it a versatile choice for domestic, agricultural, commercial, and selected industrial applications.
The replaceable membrane is especially valuable for maintenance-focused users because it may reduce the need to discard the entire pressure vessel when the internal membrane reaches the end of its service life. The availability of Butyl and EPDM options allows the tank to be matched more closely to the water, temperature, and operating conditions of the installation.
With capacities from 60 to 300 liters and maximum pressure options up to 16 bar, the series can support both compact booster systems and larger water-pressure installations. The horizontal design can also provide flexibility where vertical equipment space is limited.
Product performance ultimately depends on correct model selection, proper precharge adjustment, suitable installation, regular maintenance, and operation within the approved pressure and temperature limits. Buyers should confirm the final technical details, particularly the temperature range and application approvals, before commissioning.
Supported by an integrated manufacturer with experience in pump research, mass production, international export, intelligent water technology, and one-stop procurement, the WCF Series offers more than a standalone vessel. It provides a practical component for complete, dependable, and maintainable water-pressure solutions.
1. WCF Series Product Specification, including model capacities, dimensions, pressure ratings, precharge pressures, connector sizes, and packing volumes.
2. Manufacturer-provided product information for replaceable membrane pressure tanks, carbon steel flange construction, and Butyl and EPDM membrane options.
3. General pressure-vessel installation and maintenance principles for pump and water-supply systems.
4. General engineering guidance on pump cycling, pressure-tank sizing, precharge adjustment, and hydraulic system protection.
5. Manufacturer background information concerning research and development, mass production, global export, intelligent booster systems, solar pumping, and water-system equipment.