edwina@edwin-pump.com
HRS-EA(B) Intelligent Circulation Pump
View All Products
en
The HRS-EA(B) Series Ceramic Bearing Circulation Pump is a specialized pump designed for circulation applications. It is known for its ceramic bearing construction, which offers several advantages over traditional bearing materials.
Applications:
Heating systems in residential and commercial buildings
Industrial equipment cooling
Solar water heating systems
Boiler circulation systems
Technical Specifications:
Flow Rate: Up to 3.7 m³/h
Head: Up to 7 meters
Pressure: Up to 10 bar
Ambient Temperature: 0℃~40℃
Ambient Humidity: 95%
Liquid Temperature: -10℃~110℃
Voltage and Frequency: Customizable (50Hz or 60Hz)
| Setting | pump curve | Function |
| PP1 | Lowest proportional- pressure curve |
The duty point of the pump will move up or down on the lowest proportional-pressure curve, depending on heating demand.The head(pressure is reduced at falling heating demand and increased at rising heating demand) |
| PP2 | Highest proportional- Pressure curve |
The duty point of the pump will move up or down on the highest proportional-pressure curve, depending on heating demand.The head(pressure is reduced at falling heating demand and increased at rising heating demand) |
| CP1 | Lowest constant- Pressure curve |
The duty point of the pump will move out or in constant-pressure curve, depending on the heating demand.The head (pressure)is kept constant, irrespective of the heating demand. |
| CP2 | Highest constant- Pressure curve |
The duty point of the pump will move out or in constant-pressure curve, depending on the heating demand. The head (pressure) is kept constant, irrespective of the heating demand. |
| III | Speed III | Pump runs at a constant speed and consequently on a constant curve.In speed lll, the pump is set to run on the Max. curve underall operating conditions. Quick venting of the pump can be obtained by setting the pump to speed lll for a short period. |
| Il | Speed Il | Pump runs at a constant speed and consequently on a constant curve.In speed ll, the pump is set to run on the Medium curve under all operating conditions. |
| I | Speed l | Pump runs at a constant speed and consequently on a constant curve. In speed l, the pump is set to run on the Min. curve under all operating conditions. |
| AUTO (EX-factory Setting) |
Under"AUTO"mode, the power of pump automatically be up or down according to flow of system in certain condition. | |
| Night Mode | Pump runs select to night mode, after one hour the power automatically down, after two hours, it will be down lowest between 5-10watt, after seven hours, the pump auto mode eliminate and recovery to original condition. |
Components :
| Part | Material |
| Pump body | Cast iron |
| Impeller | PES |
| Stainless steel cover | 304SS |
| Bearing | Ceramic |
| Gasket | Rubber |
| Brass bearing | Brass |
| Rator | SS&Copper |
| Ceramic shafting | Ceramic |
| Shielding | 304SS |
| Stator | Silicon steel&Copper |
| Motor housing | Aluminum |
| Hexagon socket screws | Stainless steel |
| Exhaust screw | Brass |
| Nameplate | Nylon |
| Seat of terminal box | Nylon |
| Cover of termial box | Nylon |






| Model | Power | Max.Flow | Max.Head | Voltage | Mater of pump body | Dimension(mm) | Weight | ||||||||||
| (W) | (m³/h) | (m) | 220V/50Hz | Cast Iron |
Plastic | Brass | Stainless steel |
L1 | L2 | B1 | B2 | H1 | H2 | G | (Kg) | ||
| 130 | 180 | ||||||||||||||||
| HRS15/4EA | 5~22 | 1.8 | 4 | ★ | ★ | ★ | ★ | ★ | 80 | 155 | 105 | 129 | 101 | 1" | 2.1 | ||
| HRS25/4EA | 2.6 | ★ | ★ | ★ | ★ | ★ | 80 | 155 | 105 | 129 | 101 | 11/2" | 2.3 | ||||
| HRS32/4EA | 3 | ★ | ★ | 80 | 155 | 105 | 129 | 101 | 2" | 2.4 | |||||||
| HRS15/5EA | 5-32 | 2.3 | 5 | ★ | ★ | ★ | ★ | ★ | 80 | 155 | 105 | 129 | 101 | 1" | 2.1 | ||
| HRS25/5EA | 3.1 | ★ | ★ | ★ | ★ | ★ | 80 | 155 | 105 | 129 | 101 | 11/2" | 2.3 | ||||
| HRS32/5EA | 3.4 | ★ | ★ | 80 | 155 | 105 | 129 | 101 | 2" | 2.4 | |||||||
| HRS15/6EA | 5~45 | 2.4 | 6 | ★ | ★ | ★ | ★ | ★ | 80 | 155 | 105 | 129 | 101 | 1" | 2.1 | ||
| HRS25/6EA | 3.6 | ★ | ★ | ★ | ★ | ★ | 80 | 155 | 105 | 129 | 101 | 11/2" | 2.3 | ||||
| HRS32/6EA | 3.6 | ★ | ★ | 80 | 155 | 105 | 129 | 101 | 2" | 2.4 | |||||||
| HRS15/7EA | 5~47 | 2.7 | 7 | ★ | ★ | ★ | ★ | ★ | 80 | 155 | 105 | 129 | 101 | 1" | 2.1 | ||
| HRS25/7EA | 3.7 | ★ | ★ | ★ | ★ | ★ | 80 | 155 | 105 | 129 | 101 | 11/2" | 2.3 | ||||
| HRS32/7EA | 3.7 | ★ | ★ | 80 | 155 | 105 | 129 | 101 | 2" | 2.4 | |||||||
| Model | Power | Max.Flow | Max.Head | Voltage | Mater of pump body | Dimension(mm) | Weight | ||||||||||
| (W) | (m³/h) | (m) | 220V/50Hz | Cast Iron |
Plastic | Brass | Stainless steel |
L1 | L2 | B1 | B2 | H1 | H2 | G | (Kg) | ||
| 130 | 180 | ||||||||||||||||
| HRS15/4EAB | 5~22 | 1.8 | 4 | ★ | ★ | ★ | ★ | ★ | 106 | 96 | 46 | 165 | 136 | 1" | 2.1 | ||
| HRS25/4EAB | 2.6 | ★ | ★ | ★ | ★ | ★ | 106 | 96 | 46 | 165 | 136 | 11/2" | 2.3 | ||||
| HRS32/4EAB | 3 | ★ | ★ | 106 | 96 | 46 | 165 | 136 | 2" | 2.5 | |||||||
| HRS15/5EAB | 5-32 | 2.3 | 5 | ★ | ★ | ★ | ★ | ★ | 106 | 96 | 46 | 165 | 136 | 1" | 2.1 | ||
| HRS25/5EAB | 3.1 | ★ | ★ | ★ | ★ | ★ | 106 | 96 | 46 | 165 | 136 | 11/2" | 2.3 | ||||
| HRS32/5EAB | 3.4 | ★ | ★ | 106 | 96 | 46 | 165 | 136 | 2" | 2.5 | |||||||
| HRS15/6EAB | 5~45 | 2.4 | 6 | ★ | ★ | ★ | ★ | ★ | 106 | 96 | 46 | 165 | 136 | 1" | 2.1 | ||
| HRS25/6EAB | 3.6 | ★ | ★ | ★ | ★ | ★ | 106 | 96 | 46 | 165 | 136 | 11/2" | 2.3 | ||||
| HRS32/6EAB | 3.6 | ★ | ★ | 106 | 96 | 46 | 165 | 136 | 2" | 2.5 | |||||||
| HRS15/7EAB | 5~47 | 2.7 | 7 | ★ | ★ | ★ | ★ | ★ | 106 | 96 | 46 | 165 | 136 | 1" | 2.1 | ||
| HRS25/7EAB | 3.7 | ★ | ★ | ★ | ★ | ★ | 106 | 96 | 46 | 165 | 136 | 11/2" | 2.3 | ||||
| HRS32/7EAB | 3.7 | ★ | ★ | 106 | 96 | 46 | 165 | 136 | 2" | 2.5 | |||||||

A self-priming jet pump is designed to make water transfer easier by reducing the need for repeated manual priming. This...
READ MOREA submersible pump often works in challenging environments where water, pressure, vibration, and continuous operation pl...
READ MOREA single water source often needs to support more than one purpose. Residential properties may require water for bathroo...
READ MORE
Starting pressure : 1.2bar - 3.0barMax. Rated Current : 10AMax. Allowable Press...
See Details
Starting pressure : 1.2bar - 3.0bar Max. Rated Current : 10A Max. Working Pressu...
See Details
Max. Using Current : 10A Max. Working Pressure : 10bar Rated Voltage : 110V-120...
See Details
Strong driving force Brass Impeller Self-priming JET Pump pump with Gasket
See Details
Rated input voltage : AC220V/50Hz-60Hz Rated output power : 0.18-1.5kW Protectio...
See Details
Manual acting control box of three-phaseFor motor power no more than 37kW(50HP)
See Details