edwina@edwin-pump.com
EMF Series Guide Vane Cover Configuraion Bearing Sleeve Design Stainless Steel Horizontal Multistage Pump
View All Products
en
Guide Vane Cover Configuraion
Stainless Steel material
Horizontal Multistage Pump
Whether you require a reliable water supply for your industrial processes or need to maintain a constant water pressure in your residential or commercial building, EMF-(T) Series Heating and Cooling Type Cast Iron Horizontal Multistage Pump is here to deliver.
1、Guide vane cover configuraion
2、Bearing sleeve design
3、Horizontal configuration : The horizontal design ensures a compact footprint, making it suitable for installations where space is limited.
4、Multistage pump : It is engineered with precision and is made from high-quality materials to ensure durability and longevity. Its advanced design allows it to operate quietly and efficiently, making it an excellent choice for those who require a reliable and efficient water pump.
Water treatment processes. Industrial cleaner. Water boosting on process, Heating and cooling for industrial process.Air-conditioning system, Airfreshening, heater device(soft water).Fertilization/metering system. Water supply and boosting(drinking water, light chlorine water).
When the density or viscosity of to be conveyed liquid is larger than of water, it is necessary to select a driving motor of high power.
Max.working pressure: 1.0MPa
Thermal protector for single phase
Environmental temperature:s+50℃
2-pole induction motor;
Single-phase:1x220~240V/50Hz;1×110~120V/50Hz;
Three-phase: 3×380~415V/50Hz;
Insulation class:F
Motors of other voltages are avaailable upon request.

|
Materials Table |
||
|
NO. |
Part |
Material |
|
1 |
Pump Casing |
HT200 |
|
2 |
Clip |
|
|
3 |
Pump Body | |
|
4 |
Shaft and Rotor |
|
|
5 |
Motor Case |
Aluminum |
|
6 |
Ball Bearing |
|
|
7 |
Motor Cover |
Cast iron |
|
8 |
Fan |
|
|
9 |
Fan Cover |
|
|
10 |
Guide vane cover |
|
|
11 |
Impeller | Stainless Steel |
|
12 |
Diffuser |
|
|
13 |
Bearing sleeve |
|
|
14 |
“O” ring |
|
|
15 |
Support |
HT200 |
|
16 |
Capacitor Holding Box |
|
|
17 |
Capacitor |
|
| Model | Power | Rated head | Rated flow | Max.Suction | G.W |
| KW | m | m³/h | m | kg | |
| EMF2-20(T) | 0.37 | 14 | 2 | 5 | 8 |
| EMF2-30(T) | 0.37 | 21 | 5 | 8.5 | |
| EMF2-40(T) | 0.55 | 28 | 5 | 9.5 | |
| EMF2-50(T) | 0.55 | 35 | 5 | 11 | |
| EMF2-60(T) | 0.75 | 42 | 5 | 12 | |
| EMF4-20(T) | 0.55 | 15 | 4 | 5 | 9.7 |
| EMF4-30(T) | 0.75 | 22 | 5 | 11 | |
| EMF4-40(T) | 0.75 | 30 | 5 | 11.5 | |
| EMF4-50(T) | 1 | 38 | 5 | 12.5 | |
| EMF4-60(T) | 1.1 | 45 | 5 | 13.5 | |
| EMF8-10(T) | 0.55 | 12 | 8 | 5 | 10.5 |
| EMF8-15(T) | 0.75 | 20 | 5 | 12 | |
| EMF8-20(T) | 1 | 24 | 5 | 14 | |
| EMF8-25(T) | 1.5 | 27 | 5 | 17 | |
| EMF8-30(T) | 1.85 | 36 | 5 | 21.5 | |
| EMF8-35(T) | 2.2 | 43 | 5 | 23 | |
| EMF8-40(T) | 2.2 | 48 | 5 | 24 | |
| EMF8-10B(T) | 0.55 | 9 | 8 | 5 | 10 |
| EMF8-20B(T) | 0.75 | 19 | 5 | 11.5 | |
| EMF8-30B(T) | 1.1 | 26 | 5 | 13 | |
| EMF8-40B(T) | 1.5 | 37 | 5 | 16 | |
| EMF8-50B(T) | 2.2 | 46.5 | 5 | 25 | |
| EMF12-10(T) | 1 | 13.5 | 12 | 5 | 12 |
| EMF12-15(T) | 1.5 | 20 | 5 | 13.5 | |
| EMF12-20(T) | 1.85 | 28 | 5 | 21 | |
| EMF12-25(T) | 2.2 | 33.5 | 5 | 24 | |
| EMF12-30(T) | 3 | 39 | 5 | 27 | |
| EMF12-10B(T) | 0.75 | 9.5 | 12 | 5 | 11 |
| EMF12-15B(T) | 1.1 | 19.5 | 5 | 13 | |
| EMF12-20B(T) | 1.85 | 29.5 | 5 | 23 | |
| EMF12-25B(T) | 2.2 | 39.5 | 5 | 24 | |
| EMF12-30B(T) | 3 | 50 | 5 | 27 | |
| EMF16-10(T) | 1 | 10 | 16 | 5 | 13.5 |
| EMF16-20(T) | 1.5 | 20 | 5 | 17 | |
| EMF16-30(T) | 2.2 | 30 | 5 | 23 | |
| EMF20-10(T) | 1 | 10.5 | 20 | 5 | 20 |
| EMF20-20(T) | 1.85 | 20 | 5 | 22 | |
| EMF20-30(T) | 3 | 31.5 | 5 | 25 |
| Model | Single Phase | Three Phase | ||||||
| L1 | L2 | L3 | H | L1 | L2 | L3 | H | |
| EMF2-20(T) | 400 | - | - | 217 | 400 | - | . | 214 |
| EMF2-30(T) | 400 | - | - | 217 | 400 | - | - | 214 |
| EMF2-40(T) | 400 | - | - | 217 | 400 | - | - | 214 |
| EMF2-50(T) | 400 | - | - | 217 | 400 | - | - | 214 |
| EMF2-60(T) | 400 | - | - | 217 | 400 | - | - | 214 |
| EMF4-20(T) | 400 | - | - | 217 | 400 | - | . | 214 |
| EMF4-30(T) | 400 | - | - | 217 | 400 | - | - | 214 |
| EMF4-40(T | 400 | - | - | 217 | 400 | - | - | 214 |
| EMF4-50(T) | 400 | - | - | 217 | 400 | - | - | 214 |
| EMF4-60(T) | 400 | - | - | 217 | 400 | - | - | 214 |
| EMF8-10(T) | 424 | - | - | 227 | 424 | - | - | 222 |
| EMF8-15(T) | 424 | - | - | 227 | 424 | - | - | 222 |
| EMF8-20(T) | 424 | - | - | 227 | 424 | - | - | 222 |
| EMF8-25(T) | 459 | - | - | 235 | 459 | - | - | 232 |
| EMF8-30(T) | 500 | - | - | 239 | 459 | - | - | 232 |
| EMF8-35(T) | 500 | - | - | 239 | 459 | - | - | 232 |
| EMF8-40(T) | 500 | - | - | 239 | 459 | - | . | 232 |
| EMF8-10B(T) | 425 | 180 | 139 | 227 | 425 | 180 | 139 | 224 |
| EMF8-20B(T) | 425 | 180 | 139 | 227 | 425 | 180 | 139 | 224 |
| EMF8-30B(T) | 461 | 180 | 139 | 235 | 455 | 180 | 139 | 232 |
| EMF8-40B(T) | 461 | 180 | 139 | 235 | 455 | 180 | 139 | 232 |
| EMF8-50B(T) | 566 | 246 | 205 | 239 | 522 | 246 | 205 | 232 |
| EMF12-10(T) | 424 | - | - | 227 | 425 | - | - | 222 |
| EMF12-15(T) | 459 | - | - | 235 | 459 | - | - | 232 |
| EMF12-20(T) | 500 | - | - | 239 | 459 | - | - | 232 |
| EMF12-25(T) | 500 | - | - | 239 | 459 | - | - | 232 |
| EMF12-30(T) | - | - | - | - | 518 | - | - | 239 |
| EMF12-10B(T) | 425 | 180 | 139 | 227 | 425 | 180 | 139 | 222 |
| EMF12-15B(T) | 461 | 180 | 139 | 235 | 455 | 180 | 139 | 227 |
| EMF12-20B(T) | 500 | 180 | 139 | 239 | 455 | 180 | 139 | 227 |
| EMF12-25B(T) | 500 | 180 | 139 | 239 | 455 | 180 | 139 | 227 |
| EMF12-30B(T) | - | - | - | - | 564 | 246 | 205 | 239 |
| EMF16-10(T) | 425 | 175 | 136 | 245 | 425 | 175 | 136 | 224 |
| EMF16-20(T) | 455 | 175 | 136 | 254 | 455 | 175 | 136 | 232 |
| EMF16-30(T) | 520 | 201 | 162 | 239 | 520 | 201 | 162 | 232 |
| EMF20-10(T) | 425 | 175 | 136 | 245 | 425 | 175 | 136 | 224 |
| EMF20-20(T) | 498 | 175 | 136 | 239 | 455 | 175 | 136 | 232 |
| EMF20-30(T) | - | - | - | - | 540 | 201 | 162 | 239 |

Industrial projects depend on stable fluid transfer systems to maintain production efficiency, resource management, and ...
READ MOREHot water recirculation systems are designed to solve one common household problem: waiting too long for hot water. By c...
READ MOREA self-priming jet pump is designed to make water transfer easier by reducing the need for repeated manual priming. This...
READ MORE
Zinc Alloy Bottom Antifatiguefor water pumpsPressure range : 15-100psiPressure s...
See Details
Fixed diaphram membrane, carbon steel tank Pre-charge pressure of 1.5bar Max. wo...
See Details
Stainless steel Working temperature: -20°C~99°C (Butyl) -20°C~99°C (EPDM) 0°C~77...
See Details
Water Shortage ProtectionVoltage StabilizationStainless Steel ConstructionVertic...
See Details
Strong driving force Brass Impeller Self-priming JET Pump pump with Gasket
See Details
Rated input voltage : AC380V, Three phase 50Hz/ 60HzRated output power : 0.35-7 ...
See Details